1-4
installation
MERCHANDISER LEVELING
B
e sure to position merchandisers properly
Level the merchandiser by all four corners .
Merchandiser(s) must be installed level to
ensure proper operation of the refrigeration
system, and to ensure proper drainage of
defrost water .
OPTIONAL LEGS
NSF
approved legs replace the leg levelers if
®
required by local health codes . The legs raise
the case 6 inches for cleaning purposes . An
optional skirt kit can be provided to snap on
the legs .
SERIAL PLATE LOCATION
The serial plate is located on the interior top,
left side of the merchandiser . It contains all
pertinent information such as model, serial
number, amperage rating, refrigerant type and
charge . This information will be needed to install,
service or order parts for the merchandiser .
Serial Plate
P/N 3109358_B
REFRIGERATION UNIT ACCESS
.
The lower front panel may be removed by
removing screw at bottom and lifting the panel
straight upward and over the tabs on which it
is hanging . The panel is installed by reversing the
above procedure .
Ensure lower front panel is flat against the
floor when installed to prevent air circulation
problems for self contained merchandisers .
Front Panel
SEALING MERCHANDISER TO FLOOR
If required by local sanitary codes, or if the
customer desires, merchandisers may be sealed
to the floor using a vinyl cove base trim . The
size needed will depend on how much variation
there is in the floor, from one end of the
merchandiser to the other . Sealing of the lower
front and rear panels on self contained models
may hamper their removal for servicing or
maintenance of the condensing unit .
NOTE: Do not allow trim to cover any intake
or discharge grilles located in the lower front
panel .
U.S. & Canada 1-800-922-1919 • Mexico 01 800-890-2900 • www.hussmann.com
Controller
Display
Lift up and
out to remove
access panel
Display is mounted on left
side of access panel . Be
careful not to detach cable
from display when removing
access panel .