Problem
Unit runs but
produces very
little ice.
(continued)
Ice is slow to
release or does
not release from
the evaporator.
Poor ice quality.
(soft or unclear)
Unit produces
shallow or
incomplete cubes,
or the ice fill
pattern on the
evaporator is
incomplete.
Possible Cause
Scale and mineral
buildup in unit.
Inadequate airflow at
the front of the unit.
Ice-making system
is dirty.
Unit is not level.
Low air temperature
around unit.
Poor incoming water
quality.
Ice-making system is
dirty.
Low water level.
Hot incoming water.
Incorrect incoming
water pressure.
Unit is not level.
37
Remedy
Clean unit. See
MAINTENANCE.
Remove items blocking
airflow.
Run unit through
automatic clean cycle.
See MAINTENANCE.
See LEVELING THE
UNIT.
Surrounding air
temperature must be
at least 50°F (10°C).
Consult a qualified
plumber to test the
water quality and
recommend appropriate
treatment.
Run unit through
automatic clean cycle.
See MAINTENANCE.
Check to see that
overflow tube is fully
seated.
Connect the unit to a
cold water supply.
See INSTALLATION.
Water pressure must
be 20-120 psi.
See LEVELING THE
UNIT.