BEFORE CALLING FOR SERVICE
If the unit appears to be malfunctioning, read through NORMAL OPER-
ATION first. If the problem persists, check the TROUBLESHOOTING
GUIDE. Locate the problem in the guide and refer to the cause and its
remedy before calling for service. The problem could be something very
simple which can be solved without a service call.
TROUBLESHOOTING GUIDE
Troubleshooting — What to check when problems occur
Problem
The unit does
not operate.
Unit runs but no
ice is produced.
Unit runs but
produces very
little ice.

TROUBLESHOOTING

!
DANGER
ELECTROCUTION HAZARD
NEVER attempt to repair or perform mainte-
nance on the unit until the main electrical
power has been disconnected.
Possible Cause
No electrical power
to the unit.
Cycle selector switch
set improperly.
Low air temperature
around unit.
No water being
supplied to the unit.
Dirty condenser coils.
High air temperature
around unit.
!
Make sure power cord
is plugged in. Check for
blown fuse or tripped
circuit breaker.
Make sure cycle selector
switch is set to ICE/ON.
Surrounding air
temperature must be at
least 45°F (7°C).
Check to see that water
is connected and turned
on to the unit.
Clean the condenser.
See MAINTENANCE.
Surrounding air
temperature of over
90°F (32°C). Low ice
production at high
temperatures is normal.
36
Remedy