INLET SCREEN CLEANING — EVERY YEAR
The solenoid valve inlet screen must be cleaned at least once each year
as follows:
1. Shut off the water at the water supply valve.
2. Pull the unit out to access the back panel.
3. Disconnect electrical power to
the unit.
4. Disconnect the hose connec-
tor from the water solenoid
valve (Figure 35).
5. Use a tooth brush to clean
sediment
screen. DO NOT remove the
screen.
6. Re-connect the water supply
line to the water solenoid
valve.
Tighten
securely. Open the water
supply valve and check for
leakage at the water connec-
tion. Make sure the water
supply line is not kinked.
7. Reconnect power to the unit before re-installing.
8. Make sure the drain system is working properly and the drain hose
is not pinched or kinked. Pour one gallon of cool, fresh water into
the ice bin. The water should drain freely. If your CLRCO2075 is
equipped with a drain pump, the pump should drain the ice bin.
from
the
inlet
connector
WATER
SOLENOID VALVE
WATER SUPPLY LINE
Figure 35