Adjusting The Secondary And Monitor Interlock Switches - New Switch Setup; Secondary And Monitor Safety Switch Parts - TurboChef NGC-1007 Service Manual

Ngc (tornado) oven
Table of Contents

Advertisement

3 3 : Secondary/Monitor Adjustment and Parts -
F I G U R E
New Switch Setup
ADJUSTING THE SECONDARY AND MONITOR
INTERLOCK SWITCHES - NEW SWITCH SETUP
1. Disconnect power to the unit.
2. Disconnect the 40-pin connector from the I/O
board to allow maximum clearance.
3. Using the 0.060" (1.524 mm) spacer as a
template (included with item 74), adjust the
secondary switch.
: This will also adjust the monitor switch.
NOTE
4. Open and close the door several times to verify
the switch gap.
: The absolute maximum gap should not
NOTE
exceed 0.060" (1.524 mm).
5. Re-connect the 40-Pin connector to the I/O
board and apply power to the unit.
6. Simultaneously press
7. Enter 9-4-2-8, then press
8. Open the oven door and verify P, S, and M
82
80
81 82
and
keys.
BACK
ENTER
.
ENTER
78
x2
83
x2
81
80
34: Secondary/Monitor Switch Assembly -
F I G U R E
New Switch Setup
disengage in sequence.
9. Close the oven door and verify the M, S, and P
engage in sequence.
10.Energize the Microwave System and open the
door.
11.Verify the W indicator is backlit, meaning the
oven microwave system turns OFF when the
door is open.

SECONDARY AND MONITOR SAFETY SWITCH PARTS

Figure 33 and 34
77. 102804
Hinge, Right
78. 102012
Switch, Limit, Micro (x2)
79. NGC-1126
Plate, Door Switch
80. 101914
Standoff, #8-32 F/F x 1", 5/16"
DIA
81. 101915
Standoff, #8-32 M/F x 5/16",
1/4" DIA (attached to outside
of Item 80.)
82. 102921
Screw, #8-32 x 3/8"
83. 101558
Screw, 4-40 x 1.125"
THE OVEN DOOR
43
77
79
82