    Home PBXware SERVERware TELCOware SIPmon SIPProt Desktop & Mobile UADs Appliances From Bicom Systems Wiki Contents 1 Introduction 2 Video Tutorial 3 Requirements 3.1 Identifying phone model 3.2 Phone firmware 3.3 DHCP server 3.4 PBXware version 4 Installation 4.1 Power adapter 4.2 Power over Ethernet (PoE) 4.3 Find the phone IP address 4.4 Reset to factory settings...
  • Page 2: Video Tutorial

    To start and successfully complete registration of your VTech phone you need to know which phone model you will setup. From the back of each VTech phone there are exact model information that you should check. Although different phone models can have exactly the same requirements and installation...
  • Page 3: Dhcp Server

    Make sure that your phone is loaded with appropriate firmware version,2.0.3.2. To find out the firmware version of your VTech phone model open a new browser window and enter your phone IP address in order to access the phone web administration interface login screen.
  • Page 4: Power Over Ethernet (Poe)

    Do not unplug or remove power to the phone while it is updating firmware and configurations. Registering phone This chapter describes how to identify VTech phone model, requirements that must be met and how to register the phone using manual configuration or auto provisioning. The following topics are covered:...
  • Page 5: Manual Configuration

    UAD settings Navigate to Settings:UAD. Make sure VTech UAD is enabled. To check the UAD status click on the edit icon corresponding to your VTech phone. Make sure Status is set to Active, Auto provisioning is set to No, and DHCP is set to Yes.
  • Page 6 Department to which extension will belong to. Example: Sales. Click on the Save button. Registering Phone This chapter describes how to register VTech phone using Hostname or IP Address. The following topics are covered: Hostname or IP Address Hostname or IP Address...
  • Page 7: Auto Provisioning

    Enter or set the following details into the respective fields. REQUIRED FIELDS: Account Active Make sure the On radio box is selected. Register Name PBXware extension number. Example: 1003 User Name Usually the same number as the Phone Number. Password The Secret of the extension as received in the e-mail associated with this extension.
  • Page 8 UAD settings. Navigate to Settings:UAD. Make sure VTech UAD is enabled. To check the UAD status click on the edit icon corresponding to your VTech phone. Make sure Status is set to Active, Auto provisioning is set to Yes, and DHCP is set to Yes.
  • Page 9 Example: john.smith@bicomsystems.com Auto Provisioning Set to Yes. MAC Address Enter VTech phone MAC address. Example: 14AEDB123456. MAC address can be found at the back of the phone. Click on the Save button. Registering Phone This chapter describes how to register VTech phone using DHCP and TFTP.
  • Page 10: Configure Blf

    PBXware. If everything is done as above described, you should have successfully registered your phone to PBXware. Dial *123 to verify registration. Configure BLF This chapter describes how to configure BLF (Busy Lamp Field) for VTech VSP726. The following topics are covered: - Extension Settings...
  • Page 11: Phone Settings

    Click on Save button to save changes. Additional Configuration Template If You want to include some additional UAD configuration for VTech VSP726, just add fields to User Agent General Auto Provisioning Template in Settings -> UAD -> VTech VSP726 menu, or add them directly to the extension in UAD Auto Provisioning Template section.