  • Page 2 Please contact your local recycling authority for disposal of this product. Customer Support Customer technical support and services are provided by AudioCodes or by an authorized AudioCodes Service Partner. For more information on how to buy technical support for AudioCodes products contact...
  • Page 3 Notice Mediant 500L Gateway & E-SBC | Hardware Installation Manual The device must be installed and serviced only by qualified service personnel. For deployment in Finland, Sweden and Norway, the device must be installed only in restricted access locations that are compliant with ETS 300253 guidelines where equipotential bonding has been implemented.
  • Page 4 Notice Mediant 500L Gateway & E-SBC | Hardware Installation Manual LTRT Description 10490 Logo updated; PSTN Fallback/Analog lifeline updated. 10491 Serial cabling updated. 10492 Duration of press for default reset updated. - iv -...
  • Page 5: Table Of Contents

    Content Mediant 500L Gateway & E-SBC | Hardware Installation Manual Table of Contents 1 Introduction 2 Unpacking the Device 3 Physical Description Physical Dimensions and Operating Environment Front Panel Description LED Descriptions Power LED Status LED Rear Panel Description LAN Interface LEDs...
  • Page 6: Introduction

    Mediant 500L Gateway & E-SBC | Hardware Installation Manual Introduction This document provides a hardware description of the Mediant 500L Gateway & E-SBC (hereafter referred to as device) and step-by-step procedures for mounting and cabling the device. The device supports the following interfaces: ■...
  • Page 7: Unpacking The Device

    Ensure that in addition to the chassis, the package contains the following items: ● Four anti-slide bumpers for desktop installation ● AC/DC power adapter Check, retain and process any documents. If there are any damaged or missing items, notify your AudioCodes sales representative. - 2 -...
  • Page 8: Physical Description

    CHAPTER 3    Physical Description Mediant 500L Gateway & E-SBC | Hardware Installation Manual Physical Description This section provides a physical description of the device. Physical Dimensions and Operating Environment The device's physical dimensions and operating environment are listed in the following table:...
  • Page 9: Led Descriptions

    CHAPTER 3    Physical Description Mediant 500L Gateway & E-SBC | Hardware Installation Manual LED Descriptions The LED descriptions are provided in the subsequent subsections. Power LED The Power LED indicates whether or not the device is powered on or off, as described in the following table.
  • Page 10: Lan Interface Leds

    CHAPTER 3    Physical Description Mediant 500L Gateway & E-SBC | Hardware Installation Manual Table 3-5: Front Panel Description Item # Label Description POWER AC power supply plug entry for connecting the device to the 12V -- 3A external AC power supply adapter.
  • Page 11: Mounting The Device

    ■ Wall mounting 19-Inch Rack Mounting You can mount the device in a standard 19-inch rack, using AudioCodes 1U 19-inch rack mount shelf (not supplied). The AudioCodes 1U 19-inch rack mount shelf is not supplied with your product and can be ordered separately from an AudioCodes sales distributor.
  • Page 12 CHAPTER 4    Mounting the Device Mediant 500L Gateway & E-SBC | Hardware Installation Manual Figure 4-2: Positioning Shelf in Rack Make sure that you attach the shelf's side brackets (left and right) at the same height level in the rack so that the shelf is in a horizontal position.
  • Page 13: Wall Mounting

    CHAPTER 4    Mounting the Device Mediant 500L Gateway & E-SBC | Hardware Installation Manual Figure 4-3: Positioning the Device's Anti-Slide Rubber Legs into Shelf's Openings Make sure the device is firmly mounted on the shelf so it does not horizontally slide in any...
  • Page 14 CHAPTER 4    Mounting the Device Mediant 500L Gateway & E-SBC | Hardware Installation Manual ➢ To mount the device on a wall: Drill three holes in the wall where you want to mount the device, using the distances between the holes as shown in the following figure: ●...
  • Page 15 CHAPTER 4    Mounting the Device Mediant 500L Gateway & E-SBC | Hardware Installation Manual Insert wall anchors of the appropriate size into each hole. - 10 -...
  • Page 16 CHAPTER 4    Mounting the Device Mediant 500L Gateway & E-SBC | Hardware Installation Manual Thread screws (not supplied) into each of the wall anchors. The recommended screw type is DIN 7982 3.5x25 Phillips flat head. Make sure that the heads extend sufficiently (about 4 mm or 0.157 in.) from the wall for the device's keyholes to hang on:...
  • Page 17: Cabling The Device

    CHAPTER 5    Cabling the Device Mediant 500L Gateway & E-SBC | Hardware Installation Manual Cabling the Device This chapter describes the cabling of the device. Connecting LAN Interfaces The device's Gigabit Ethernet LAN ports (1000Base-T) can be connected to network equipment and entities such as computers, switches, and IP phones.
  • Page 18: Isdn Bri Interfaces

    CHAPTER 5    Cabling the Device Mediant 500L Gateway & E-SBC | Hardware Installation Manual ➢ To connect the device to the LAN: Connect one end of a straight-through RJ-45 Cat 5e or Cat 6 cable to the LAN port, located on the rear panel and labeled GE LAN.
  • Page 19: Connecting Pstn Fallback For Bri Lines

    CHAPTER 5    Cabling the Device Mediant 500L Gateway & E-SBC | Hardware Installation Manual BRI interface is a separate orderable item which is supported only on specific hardware configurations. For more information, contact your AudioCodes sales representative. The BRI cabling specifications include the following: ■...
  • Page 20: Analog Interfaces

    CHAPTER 5    Cabling the Device Mediant 500L Gateway & E-SBC | Hardware Installation Manual ➢ To cable the BRI PSTN Fallback: Connect BRI line 1 (Port #1), located on the rear panel, to an ISDN PBX. Connect BRI line 2 (Port #2)), located on the rear panel, to the ISDN network (PSTN).
  • Page 21: Connecting Fxo Interfaces

    CHAPTER 5    Cabling the Device Mediant 500L Gateway & E-SBC | Hardware Installation Manual ● FXS interface is a separate orderable item. ● FXS is the interface replacing the Exchange (i.e., the CO or the PBX) and connects to analog telephones, dial-up modems, and fax machines. The FXS is designed to supply line voltage and ringing current to these telephone devices.
  • Page 22 CHAPTER 5    Cabling the Device Mediant 500L Gateway & E-SBC | Hardware Installation Manual ● The device does not include primary telecom protection! When the FXO telephone lines are routed outside the building, additional protection - usually a 350V three- electrode Gas Discharge Tube (GDT) as described in ITU-T K.44 - must be provided at the entry point of the telecom wires into the building (usually on the main distribution frame / MDF), in conjunction with proper grounding.
  • Page 23: Connecting The Fxs Analog Lifeline

    CHAPTER 5    Cabling the Device Mediant 500L Gateway & E-SBC | Hardware Installation Manual Figure 5-9: Connecting FXO Interfaces Connect the other end of the cable to the required telephone interface: (e.g., telephone exchange analog lines or PBX extensions). Connecting the FXS Analog Lifeline The device supports Analog Lifeline.
  • Page 24: Cabling The Serial Interface To A Pc

    CHAPTER 5    Cabling the Device Mediant 500L Gateway & E-SBC | Hardware Installation Manual Figure 5-11: Cabling the FXS Analog Lifeline Cabling the Serial Interface to a PC The device provides an RS-232 serial interface port on its rear panel. The RS-232 interface port is used to access the device's command line interface (CLI).
  • Page 25: Connecting A Usb Storage Device

    CHAPTER 5    Cabling the Device Mediant 500L Gateway & E-SBC | Hardware Installation Manual Figure 5-12: Cabling Serial Port Connect the other end of the cable (e.g., 9-pin DB connector) to the COM RS-232 communication port on your computer. Connecting a USB Storage Device The device supports USB storage capabilities, using an external USB hard drive or flash disk (disk on key) connected to the device's USB port.
  • Page 26: Connecting To The Power Supply

    ご注 意 本 製 品 に添 付 の電 源 ケーブルは、 Mediant 500L Gateway & E-SBC に専 用 設 計 さ れて いるため、 汎 用 性 があり ません. 本 電 源 ケーブルを他 の機 器 に使 用 さ れないよう 、 ご注 意...
  • Page 27 CHAPTER 5    Cabling the Device Mediant 500L Gateway & E-SBC | Hardware Installation Manual Table 5-4: Power Adapter with Interchangeable Plugs Item Description Plug slot Plug lock Plug release lever DC power cord DC power plug ➢ To connect the device to the power supply using the power adapter: Insert the relevant AC plug into the housing power adapter: Insert the top part of the plug into the upper part of the housing slot (1).
  • Page 28: Powering On Or Off The Device

    CHAPTER 5    Cabling the Device Mediant 500L Gateway & E-SBC | Hardware Installation Manual Figure 5-16: Cabling to Power using Power Adapter Plug the power adapter directly into a standard electrical wall outlet. Powering On or Off the Device The device is equipped with a power switch, which is located on its rear panel (see...
  • Page 29 CHAPTER 5    Cabling the Device Mediant 500L Gateway & E-SBC | Hardware Installation Manual This page is intentionally left blank. - 24 -...
  • Page 30 Website: https://www.audiocodes.com/ ©2019 AudioCodes Ltd. All rights reserved. AudioCodes, AC, HD VoIP, HD VoIP Sounds Better, IPmedia, Mediant, MediaPack, What’s Inside Matters, OSN, SmartTAP, User Management Pack, VMAS, VoIPerfect, VoIPerfectHD, Your Gateway To VoIP, 3GX, VocaNom, AudioCodes One Voice, AudioCodes Meeting Insights, AudioCodes Room Experience and CloudBond are trade- marks or registered trademarks of AudioCodes Limited.