Tripp Lite B096-048 Owner's Manual page 201

Console server management switch & console server with poweralert
Hide thumbs Also See for B096-048:
Table of Contents

Advertisement

- Select Status: Support Report
- Scroll down to Processes
- Look for: /bin/ssh -MN -o ControlPath=/var/run/cascade/%h Slavename
- These are the Slaves that are connected
- Note: The end of the Slaves' names will be truncated, so the first 5 characters must be unique
Alternatively, you can write a custom CGI script as described above. The currently connected Slaves can
be determined by running: ls /var/run/cascade and the configured Slaves can be displayed by running:
config -g config.cascade.Slaves