Radio Shack iSCAN PRO-18 User Manual page 42

Trunking scanner
Table of Contents

Advertisement

Code
Meaning
MicroSD Card is full
03-05
MicroSD Card is
03-06
write protected
Mass storage mode
03-07
is active
Unknown MicroSD
03-08
card read/write error
Initialization error
04-00
Initialization error
04-01
Firmware load error
04-02
Unable to load
05-00
CONFIG__.BIN
CONFIG__.BIN file
05-01
error
CONFIG__.BIN file
05-02
error
CONFIG__.BIN file
05-03
error
2000018.UG.031011.indd 42
Corrective Action
Reduce size of configuration, remove
unnecessary files or switch to a MicroSD
card with more capacity.
Reinsert the MicroSD card to ensure it is
fully inserted. If necessary, reformat the
MicroSD card using the PC Application
"Prepare SD Card for use" option.
Replace the MicroSD card if the problem
persists.
Mass storage device mode should be
disabled when iSCAN is connected to
a computer and scanning. Disconnect
iSCAN from the computer, wait a few
seconds, then reconnect.
Reinsert the MicroSD card to ensure it
is fully inserted in locked in the MicroSD
slot. If necessary, reformat the MicroSD
card using the PC Application "Prepare
SD Card for use" option. Replace the
MicroSD card if the problem persists.
Contact RadioShack Support and provide
error code information
Reformat the MicroSD card using the PC
Application "Prepare SD Card for use"
option. Replace the MicroSD card if the
problem persists.
42
3/10/2011 11:07:03 AM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2000018