IMPORTANT!
This range must be connected to the mains power supply only by a suitably
z
qualified person.
This range must be earthed.
z
Always disconnect electric supply cord from the wall outlet or service disconnect
z
before servicing this appliance.
Observe all governing codes and ordinances when grounding, in absence of which,
z
observe National Electrical Code ANSI / NFPA No. 70.
Wiring diagrams are
also in the service
summary, attached
to the inside of the
kick panel
16
ELECTRICAL CONNECTION
RDV3 models
A neutral supply wire must be provided from the power source (breaker panel)
z
because critical range components, including the surface burner spark reignition module,
require 120/240 VAC to operate safely and properly.
If the correct power supply circuit is not provided, it is the responsibility and
z
obligation of the installer and user to have proper power supply connected.
This must be accomplished in accordance with all applicable local codes and ordinances
by a qualified electrician. It is the responsibility of the installer to ensure compliance
of local codes. In the absence of local codes and ordinances, the power supply
connection shall be in accordance with the National Electric Code.
Observe all governing codes and ordinances when grounding. In the absence of these
z
codes or ordinances observe National Electrical Code ANSI/NFPA No. 70 current issue.
See the following information in this section for grounding method..
The ranges are to be connected to a 240/208 VAC power supply.
z
IMPORTANT!
An improper 120/240 VAC power supply will cause malfunction, damage to this
z
appliance, and possibly create a condition of shock hazard.
Improper connection of aluminum house wiring can result in a fire or shock hazard.
z
Use only connectors designed and certified for connecting to aluminum wire.
The rating
label is located
on the back of
the range
MODEL
RDV3-304
RIV3-304
RDV3-366
A wiring
RIV3-365
diagram label
is attached to
RDV3-488
the back of
RDV3-485GD
the range
RHV3-484
IMPORTANT!
The fourth prong (round grounding pin) should not, under any circumstances,
be cut or removed.

MAX.

CIRCUIT
FREQUENCY
CURRENT DRAW
27 A
30 A
57 A
50 A
29 A
30 A
72 A
50 A
44 A
50 A
44 A
50 A
75 A
50 A
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz