The panel shows SN1
Open sensor (heater is deactivated) or short circuited sensor (mi-
ni-pool is deactivated). The upper-limit temperature sensor is
not functioning.
I Contact an authorized Jacuzzi Service Centre.
The panel shows SN2
Open or short-circuited sensor (heater disabled). The tempera-
ture sensor is not functioning.
I Contact an authorized Jacuzzi Service Centre.
The panel displays FL1 or FL2
(models without circulation pump)
If the message "FL1" flashes on the display, it means that the pressure
switch is not working perfectly when pump 1 is activated.
A flashing "FL2" display means the flow switch is malfunctioning
closed.
This error will cause the heater to deactivate.
- To correct the situation:
I Check that the water level is about 3 cm from the lowest
headrest. Add water if necessary.
I Check for clogged/excessively dirty filter cartridge.
I Eliminate any air locks from pump 1 by unscrewing the up-
per drain plug for a few seconds. Then screw the plug back in.
I If the problem persists, contact an authorized Jacuzzi serv-
ice centre.
The panel displays FL1 or FL2
(models with circulation pump)
If the message "FL1" flashes on the display it means that the flow
switch is not working perfectly, the cartridge of the filter is dirty or
there is air trapped in the circulation pump. A flashing "FL2" display
means the pressure switch is not properly closed.
This error causes deactivation of the heater. Pump 1 might be de-
activated as well.
- To correct the situation:
I Check that the water level is about 3 cm from the lowest
headrest. Add water if necessary.
I Check for clogged/excessively dirty filter cartridge.
I Eliminate any air locks from the circulation pump. Remove the
filter cartridge and insert a garden hose in the housing of the car-
tridge. Place a rag to seal the opening connected to the pump.
Open the water for about 30 seconds; then close it and put the
filter back in place. Check the operation of the spa.
I If the circulation pump is not working, turn the main switch
off and on to prime it again.
I If the problem persists, contact an authorized Jacuzzi serv-
ice centre.
The panel shows COL
The temperature has dropped 11°C below the set temperature.
Pump 1 (or the circulation pump, if included) and the heater are
activated to bring the temperature to 8 C° from the set temper-
ature.
I No corrective action is required.
N.B.: this is a normal condition during the first filling of the spa, s-
ince tap water is often very cold. "COL" will only appear when the s-
pa is in Economy mode.
The panel shows ICE
Freeze Protection - A potential freeze condition has been detected.
I No operation is required. The main pump (or the circulation
pump, if included) and the heater will activate to circulate
warm water through the plumbing until the pool is out of
danger.
N.B.: "ICE" will only appear when the spa is in Economy mode.
Panel displays - - -
The safety software has been activated and the spa is deacti-
vated; a problem has been detected which may damage the spa
or its components.
I Contact an authorized Jacuzzi Service Centre.