Commissioning (software)
4.2 Configuring the system in offline mode
Note
If the message frames for drive objects (Control Unit, Drive, Terminal Modules, etc.)
change, you must perform HW Config alignment again. The addresses are not updated
automatically.
4.2.5

Downloading a project created offline to the target system

Procedure
1. Save and compile the project.
2. Go online to SIMOTION D410.
3. Select the "Download project to target system" command to download the project to
4. Execute the "Copy RAM to ROM ..." function on the D410 and SINAMICS Integrated.
Drive programming and commissioning is completed. You can now test the drive using the
drive control panel.
Note
Online access to SINAMICS Integrated is not possible if HW Config is not loaded at the time
you initially connect to the target system.
Download the data to HW Config in order to enable online access to SINAMICS Integrated.
70
SIMOTION D410. The connection to SINAMICS Integrated is activated automatically.
This saves the project on the CompactFlash Card, meaning that it does not need to be
reloaded after switching off and on again.
D410
Commissioning Manual, 05/2009