GRAUPNER GM Genius Pro Series Manual page 23

Speed controller with telemetry and w-lan module (optional)
Table of Contents

Advertisement

Warning messages
Setting the alarm thresholds
[ESC]
*SENSOR
>User setup
:
page 1
>MODEL
:
E.S.C save?
Factory set?
E.S.C RESTART...
>Ver:P 2.080
S3084_S3086_S3078_S3085_MP_V1
Indicators in the telemetry menu
Minimum battery voltage (Page 2)
Minimum battery voltage: Warning threshold for the minimum bat-
tery voltage during operation, warning threshold adjustable between
3.0 and 23.0 V
Factory setting: 3.0 V, signal tone: P
Warning: Off
Maximum speed controller temperature (Page 3)
Maximum speed controller temperature (temperature): Warning
threshold for the maximum speed controller temperature during
operation, warning threshold adjustable between 10 and 120°C.
Factory setting: 100°C, signal tone: H
Warning: Off
Maximum motor temperature (Page 4)
Maximum motor temperature (temperature): Warning threshold for
the maximum motor temperature during operation, warning thresh-
old adjustable between 10 and 120°C. Only for motors with sensor.
Factory setting: 100°C, signal tone: I
Warning: Off
Maximum current (Page 5)
Maximum current: Warning threshold for the maximum current of
the motor, warning threshold adjustable between 25 and 200A.
Note: The warning threshold should never be programmed higher
than the maximum permissible current of your speed controller type
in order to get a reasonable warning!
Factory setting: according to the ESC, signal tone: W
Warning: Off
Thresholds and settings storage
<>
To save the settings in the speed controller, go back to the display
"page 1 - ESC MODEL" and select the menu point "E.S.C save". Push-
ing the "SET" button the parameter is represented inversed. Change
to YES and push the "SET" button to save the selected setting. An
additional line "E.S.C RESTART" is displayed and starts with a 3 count-
down. When 0 is entered, the settings are permanently stored, as
confirmation, "E.S.C RESTART" is dimmed again. If you do not want
to save the adjustments, select NO.
Note
If settings are changed and then not saved, the motor will not start.
This is an additional security feature, not to forget to save.
23 / 32

Advertisement

Table of Contents
loading

Table of Contents