Boost
Boost "ON"
18 / 32
Boost Max-rpm
Set the maximum RPM limit for the boost timing. For example,
with a boost value set to 20-degrees and maximum RPM set at
20000, the boost will cap out and hold at 20-degrees once the ESC
crests 20000. This option can be set between 0~65000 but cannot
be lower than the Boost Min RPM.
Boost-TH. Limit
Boost Throttle Limit Mode sets the boost timing limit within 5
steps of the throttle location. (Boost OFF and ON are not supported.)
Refer to the graphs below.
Throttle
Limit
rpm
Turbo Delay
Delay the turbo activation. Turbo is immediately activated
when the delay value is set as "0.00" and the throttle is moved to
"full". When a value is entered, the turbo is only activated after the
throttle is moved to full and the set delay time has elapsed.
Turbo + Slope
Set the amount of time it takes to reach turbo speeds after
activation. The lower the value, the more the acceleration and heat-
ing is increased.
Turbo – Slope
Set the amount of time it takes to recover from turbo speeds
when the throttle is back to the original location. The lower the
value, the more the brake effect and vehicle movement is decreased.
Acceleration (acceleration, soft throttle)
You use this function to specify how quickly the throttle commands
are transmitted to the motor.
Influences the run-up behavior of the motor. A lower value corre-
sponds to softer start-up of the motor; a higher value means some-
what more power.
Boost
Boost +"TH"
S3084_S3086_S3078_S3085_MP_V1