GRAUPNER GM Genius Pro Series Manual page 13

Speed controller with telemetry and w-lan module (optional)
Table of Contents

Advertisement

Settable values in the program
Programmable
Parameter Values
Items
Motor Type
Select Battery
LiPo / LiFe / NiMH (NiCd)
Disable / Auto / 3.0V ~ 7.5V (Step:0.1V)
Cut Off Voltage
Disable / Auto / 6.0V ~ 23V (Step:0.1V)_S3085
Power Curve
0 ~ 10
Boost
Off
Boost Max+TB
ON
+TH
Boost Min-rpm
0 ~ 64500 (Step: 500 rpm)
Boost Max-rpm
0 ~ 65000 (Step: 500 rpm)
TH
20%
40%
Boost-TH. Limit
60%
80%
100%
Turbo Delay
0.00 ~ 1.00s (Step: 0.05s)
Turbo + Slope
0.00 ~ 1.00s (Step: 0.05s)
Turbo - Slope
0.00 ~ 1.00s (Step: 0.05s)
Acceleration
0 ~ 10
Start Power
0 ~ 100 (Step: 1%)
Start Curr Limit
Off, 1% ~ 100% (Step: 1%)
Current Limit
Off, 1% ~ 100% (Step: 1%)
Reverse Function
One Way / Two Way / Two Way 2 / Two Way 3
Reverse Delay
Off / 0.2s / 0.5s / 0.8s / 1.3s / 1.8s / 2.5s
M-Reverse Amount
20 ~ 100% (Step: 1%)
Neutral Width
Narrow / Normal / Wide
Motor Direction
Normal / Reverse
Brake Response
0% ~ 100% (Step: 1%)
A.B.S. Brake
Off / Weakest / Weak / Normal / Strong / Strongest
Drag Brake
0% ~ 100% (Step: 1%)
Min Brake Amount
0% ~ 100% (Step: 1%)
Mid Brake Amount
0% ~ 100% (Step: 1%)
Mid Brake Location
0% ~ 100% (Step: 1%)
Max Brake Amount
0% ~ 100% (Step: 1%)
Soft Brake
Hard / Soft
Brake Freq
1KHz / 2KHz / 5KHz / 8KHz / 16KHz / 32KHz
Motor Freq
1KHz / 2KHz / 5KHz / 8KHz / 16KHz / 32KHz
Drag Freq
1KHz / 2KHz / 5KHz / 8KHz / 16KHz / 32KHz
Cut Off Temp
100° ~ 135° (Step: 5) / Disable
Cut Off M-Temp
100° ~ 135° (Step: 5) / Disable
B.E.C. Voltage
6.0 / 7.4V
Current Voltage
XX.X
Current Temp
100° ~ 135°
Max Temperature
100° ~ 135°
Motor Temp
100° ~ 135°
Motor Max Temp
100° ~ 135°
Max Current
0 A ~ 999 A
Motor Pole Num
2 ~ 20 Pole
Gear ratio
2.0 : 1 ~ 15.0 : 1
Tire Diameter
40mm ~ 200mm
Motor-Wiring
A-B-C / C-B-A
Maximum Speed
XXX.X Km/h
Maximum RPM
XXX rpm
Error History
M, T1, T2, S, V, R
Download
All parameters inside the setup card are downloaded to the ESC.
Restore Memory
All setting information inside EEPROM are read via the RAM.
Backup Memory
All setting information inside the RAM are stored at EEPROM
Factory Setting
Change the setting of ESC to default status.
S3084_S3086_S3078_S3085_MP_V1
Sensor only for S3084,S3086,S3078
Max
X
0 ~ 58 (Hybrid:25)
0 ~ 58 (Hybrid:25)
Limit
0 ~ 58 (Hybrid:25)
0 ~ 58 (Hybrid:25)
0 ~ 58 (Hybrid:25)
0 ~ 58 (Hybrid:25)
0 ~ 58 (Hybrid:25)
Hybrid only for S3078,S3086,S3085
+
TB
X
0 ~ 58 (Hybrid:25)
0 ~ 58 (Hybrid:25)
Soft
8KHz / 16KHz
Default
Sensor
LiPo
Auto
5
Off
5000 rpm
25000
rpm
0
0.20s
0.20s
0.20s
5
0%
Off
Off
One Way
2.5s
100%
Wide
Normal
0%
Off
0%
30%
50%
50%
100%
Soft
1KHz
5KHz
1KHz
135°
135°
6.0V
2 Pole
2.0 : 1
63mm
A-B-C
13 / 32

Advertisement