C C h h a a p p t t e e r r 4 4 L L e e v v e e l l 2 2
P P r r o o g g r r a a m m m m i i n n g g
Used to access the following:

• Advanced Product Settings

• Error Code Log
• Password Programming

• Alert Tone/Volume

• No. Of Cook Cycles Before Filter Is Suggested
• Automatic Filter Time
4 4 . . 1 1 A A d d v v a a n n c c e e d d P P r r o o d d u u c c t t S S e e t t t t i i n n g g s s
Press the temp and info hold and buttons until "LEVEL - 2" shows in the display,
1 1 ) )
followed by "ENTER CODE".
Enter code 1, 2, 3, 4 (first 4 product buttons). "PROD" and "COMP" show in the
2 2 ) )
displays.
Press right ✓ button and "SELECT PRODUCT" "-P 1-" shows in the display.
3 3 ) )
Use the left and right arrows to scroll through the 40 products, or press the
4 4 ) )
desired product button.
Press right ✓ button and the product (ex: NUGGETS) shows in the left display,
5 5 ) )
and "MODIFY" "YES NO" shows in the right display. Press the ✓ button to
change this product, or press the "X" button to choose another product.
L L o o a a d d C C o o m m p p e e n n s s a a t t i i o o n n , , L L o o a a d d C C o o m m p p e e n n s s a a t t i i o o n n R R e e f f e e r r e e n n c c e e , , F F u u l l l l H H e e a a t t , , P P C C F F a a c c t t o o r r
If ✓ button was pressed, "LD COMP" shows in the display along with the load
6 6 ) )
compensation value. This automatically adjusts the time to account for the size
and temperature of the cooking load. Press the product buttons to change this
value of 0 to 20.
Press the down arrow until "LCMP REF" shows in the display along with the
7 7 ) )
load compensation average temperature. (if load compensation is set to "OFF",
then "_ _ _" shows in display and setting cannot be programmed.) This is the
average cooking temperature for each product. The timer speeds up at
temperatures above this setting and slows down at temperatures below this
setting. Press the product buttons to change this value.
Press the down arrow until "FULL HT" shows in the display along with the full
8 8 ) )
heat value in seconds, which means the heat is on as soon as a timer button is
pressed, for the programmed length of time. Press the product buttons to
change this value of 0 to 90 seconds.
Press the down arrow until "PC FACTOR" shows in the display along with the
9 9 ) )
proportional temperature, which helps to keep the oil from over-shooting the set-
point temperature. Press the product buttons to change this value of 0 to 50
degrees.