2 . INTERFACE
2 .1 INPUT INTERFACE
2 .2 OUTPUT INTERFACE
Rated Speed Reference
±10V DC
Input Resistance
15K Ohms
Running Signal
+12V
OV
Run
Stop
Torque Limit
+12V
OV
Low Torque
Nigh Torque
Zero Speed Detection
Contact closes when the motor
speed drops to 1% or lower
than the rated speed
Speed Agreement
Contact closes when the motor
Detection
speed is within ±15% of the
commanded speed
Excessive Deviation
Contact closes when the motor
Detection
speed drops to 50% or less
of the commanded speed .
Trouble Detection
Contact closes or opens when
any trouble is detected .
Overload Detection
Contact closes when the
current goes over the set
current limit .
Speed Detection
Contact closes when the speed
drops under the set speed
Speed Meter Drive
One way swing DC 1mA meter
(Full scale at Max . speed)