Interface Panel - YASKAWA DX200 Instructions Manual

Options for motofit function engineering support tool
Hide thumbs Also See for DX200:
Table of Contents

Advertisement

HW1481731
4

Interface Panel

4
Interface Panel
The interface screen is configured as in the following figure. For I/O
assignment of the button switches and status display LEDs, refer to the table
below. Do not use the general output No. in the table if FSE-Tool is used.
1. Button switch
General
Signal Name Contents
Output No.
11250
Start
11251
Stop
11252
Mode switch
11230
Zero reset
11231
Coordinate
system
switch
2. Status display LED
General
Signal Name Contents
Output No.
11260
Running
11262
Mode switch
11263
TOUCH
Setting
completed
11264
FIT
Setting
completed
11265
INSERT
Setting
completed
4-1
Operation start
(Tuning Step 1, 2, TOUCH, FIT, INSERT)
Operation stop
(Tuning Step 1, 2, TOUCH, FIT, INSERT)
ON: Operation from PC (FSE-Tool) valid
OFF: Operation from PP (JOB) valid
Zero reset of the sensor value
The coordinate system while monitoring
With button depressed: LED ON
ON: [PC MODE] LED ON
OFF: [PP MODE] LED ON
With the {TOUCH COMP SET} button pressed on
PC: LED ON
Operation end: LED OFF
With the {FIT COMP SET} button pressed on PC:
LED ON
Operation end: LED OFF
With the {INSERT COMP SET} button pressed
on PC: LED ON
Operation end: LED OFF