SYMBOL
FUNCTION
ADJUSTMENT
13RH(C)
Time adjustment of
Adjust to 60-120 sec . according to
OVERLOAD detection
specification .
IORH(C)
Level adjustment of
Adjust to 110% of rated speed .
Over Speed detection
15RH(C)
Level adjustment of
Adjust to 84% of rated voltage .
Low Voltage detection
SYMBOL
FUNCTION
ADJUSTMENT
9RH(A)
Level adjustment of
Adjust within 1% of rated speed .
zero speed detection
AGREE(A)
Level adjustment of
Adjust to x_15% of commanded speed
speed agree detection
IORH(A)
Offset adjustment of
Adjust to -.15% of commanded speed at low
speed agree detection
speed range .
(-15%)
I1RH(A)
Offset adjustment of
Adjust to 1-15% of the commanded speed
speed agree detection
at low speed .
(+15%)
DEV-A(A)
Level adjustment of
Adjust to 50% of the commanded speed
deviation detection
SYMBOL
FUNCTION
ADJUSTMENT
TIME(A)
Selection of acc/dec
time limit
100% speed reference
T is equal to the
time set by the
T
4 4
DIP switch .