Download Print this page

YASKAWA PS-V10S Installation Manual page 28

Ac drive-v1000 option

Advertisement

5 Installation Procedure
Wire Gauges and Tightening Torque
Tightening
Terminal
Screw
Torque
Number
Size
(N m)
0.22 to
24, 0, FE M2
0.25
Wire Gauges for Connecting Multiple Drives
The 24 V Power Supply Option can be wired to 10 drives in parallel.
proper wire gauges for connecting multiple drives.
Connection
2 to 5 drives wired in parallel
6 to 10 drives wired in parallel
Disconnecting the 24 V Power Supply Option (PS-V10S / PS-V10M)
Use this procedure should it become necessary to remove the 24 V Power Supply Option
from the drive.
1. Insert a flat-blade screwdriver into the tabs on the option cover and free the option cover.
Refer to Separate the 24 V Power Supply Option Cover and Mounting Attachment on
page
17.
2. Remove connection cables by pressing on the connector release tabs at the end of each
cable to unplug the cables.
3. Remove the mounting attachment by pressing two tabs in the direction of arrows as shown
in
Figure
23.
Figure 23
28
Table 6 Wire Gauges and Tightening Torque
Bare Wire
Allowable
Gauges mm
2
(AWG)
Stranded wire,
0.25 to 1.0
(24 to 17)
Single wire, 0.25
to 1.5 (24 to 16)
Table 7 Wire Gauges for Multiple Drives
Figure 23 Removing the Mounting Attachment
YASKAWA ELECTRIC TOBP C730600 27B V1000 Option PS-V10 Installation Manual
Pluggable Terminals
Recommended
Allowable
Gauges mm
Gauges
2
(AWG)
mm
2
0.25 to 0.5
0.75 (18)
(24 to 20)
Recommended Gauges mm
0.25 to 0.5 (24 to 20)
0.5 (20)
Recommended
Gauges mm
(AWG)
(AWG)
0.5 (20)
Table 7
indicates the
(AWG)
2
Wire
Type
2
Shielded
line, etc.

Advertisement

loading

This manual is also suitable for:

Ps-v10m