Unplug Drive Cables to Install the 24 V Power Supply Option
(PS-V10S)
If you are installing 24 V Power Supply Option (PS-V10M), proceed to
Cables to Install the 24 V Power Supply Option (PS-V10M) on page
1. Unplug one end of the existing drive cable from its socket inside the drive as shown in
Figure
9. Press inward on the cable release tab in the center of the cable connector and
use a flat-blade screwdriver to gently pry up to remove the connector from its socket.
NOTICE: Do not use excessive force when using a screwdriver to free the drive cable connection. Failure to
comply may damage or break the cable connectors.
Figure 9
Figure 9 Unplugging the Drive Cable Connection (PS-V10S)
2. Next, plug the supplied 24 V Power Supply Option connection cable into the drive cable
socket and click firmly into position as shown in
Note: Refer to
Table 1
Connection cables and mounting attachments for 24 V Power Supply Options differ depending
on drive model.
Figure 10
Figure 10 Plugging the Option Connection Cable into the Drive (PS-V10S)