Omron NX1 Series Manual page 20

Machine automation controller
Table of Contents

Advertisement

Machine Automation Controller
Built-in
EtherNet/IP
OPC UA Server
port
20
NX1
Item
Support profile/Model
Default Endpoint/Port
Maximum number of sessions
(Client)
Maximum number of Monitored
Items per server
Sampling rate of Monitored Items
(ms)
Maximum number of Subscriptions
per server
Maximum number of variables to
open
Maximum number of Value
attribute of variables to open
Structure's definitions able to open 100
Restrictions on variables unable to
open
SecurityPolicy/Mode
Authentication
Maximum
Application
number of
Authentication
storable
certifications
User
Authentication
Authentication
12
11
UA 1.02 Micro Embedded Device Server Profile
PLCOpen Information Model
opc.tcp://192.168.250.1:4840/
5
2,000
0, 50, 100, 250, 500, 1000, 2000, 5,000, 10,000
(If set to 0 (zero), it is assumed that is set to 50.)
100
10,000
10,000
• Variables whose size is over 1,024 bytes
• Two-dimensional or higher structure arrays
• Structures that include two-dimensional and higher arrays
• Structures with four or higher levels of nesting
• Unions
• Arrays whose index number suffix does no start from 0
• Arrays with 1,024 or more elements
• Structures with 100 or more members
Select one of the following.
None
Sign - Basic128Rsa15
Sign - Basic256
Sign - Basic256Sha256
SignAndEncrypt - Basic128Rsa15
SignAndEncrypt - Basic256
SignAndEncrypt - Basic256Sha256
X.509
Trusted certification: 32
Issuer certification: 32
Rejected certification: 32
You can set the following items.
User name/password
Anonymous
NX102-
10
90

Hide quick links: