Connecting
To connect the field module cable, proceed as follows:
1. Open the center cover on the enclosure of the field control unit.
2. Connect the cable in accordance with the assignment table on the terminal block. An
overview of the terminal assignments can be found on the inside of the cover when removed.
3. Connect the gas connections on the field module, see →Gas connections (Page 50).
4. Check the gas paths for leaks, see →Checking the sample gas path for leaks (Page 74).
5. Close the field control unit enclosure. Tighten the screws with a torque of 3.5 Nm.
See also
Installing/mounting (Page 41)
Field module cable (Page 54)
Field device
Operating Instructions, 05/2015, A5E35640463-02
Core num‐
Signal /
ber
property
1
P24 V
2
P24 V
3
P24 V
4
GNDPWR
5
GNDPWR
6
GNDPWR
7
GND
8
CANH
9
CANL
10
DO 21/1
11
DO 21/3
12
DO 21/2
Number on the termi‐
Core num‐
nal block PCB
ber
70
69
68
35
34
33
64
65
30
8
10
9
Signal /
Number on the termi‐
property
nal block PCB
13
DO 22/1
14
DO 22/3
15
DO 22/2
16
DO 23/1
17
DO 23/3
18
DO 23/2
19
AO 1P
20
AO 1N
21
AO 2P
22
AO 2N
23
AO 3P
24
AO 3N
Wiring
6.3 Field module
11
13
12
46
48
47
20
55
21
56
23
57
53