Motor Or Machine Table Creates Vibrations - Bosch Rexroth Sytronix FcP 50 Series Operating Instructions Manual

Motor-pump unit mpes2
Table of Contents

Advertisement

96/143
Bosch Rexroth AG
Troubleshooting
13.4.4

Motor or machine table creates vibrations

Possible cause
Counter measures
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
State
Vibrations on the motor are audible and noticeable.
1.
Driven machine elements are insufficiently coupled or damaged
2.
Motor bearing worn or defective
Available bearing lifetime or grease lifetime expired
3.
Motor fastening loosened
4.
Drive system is instable in terms of regulation
1.
Contact the machine manufacturer
2.
Contact the machine manufacturer
3.
Check mechanical connections. Do not use damaged parts. Contact the
machine manufacturer
4.
Check parameterization of drive system.
DOK-SYTROX-MPES2******-IT01-EN-P
Rexroth Sytronix FcP 50xx/70xx Motor-Pump Unit MPES2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth sytronix fcp 70 series

Table of Contents