Trouble Shooting - JRC JMA-610 Series Instruction Manual

River radar equipment
Hide thumbs Also See for JMA-610 Series:
Table of Contents

Advertisement

7.2

TROUBLE SHOOTING

As this radar equipment includes complicated circuits, it is necessary to request a specialist engineer for repair
or instructions for remedy if any circuit is defective.
There are also troubles by the following causes, which should be referred to in checking or repair work.
1
Poor Contact in Terminal Board of Inter-Unit Cables
a) Poor contact in terminal board
b) The cable end is not fully connected, that it, contacted with earthed another terminal.
c) Disconnected cable wire
2
Poor Contact of Connector within Unit
Reference: This radar equipment is provided with standard spares which include two kinds of fuses. Refer
to table 7-4.
Name
Type/Code
ST4-5AN1
Fuse
(5ZFCA00050)
ST6-8AN1
Fuse
(5ZFCA00052)
Parts No.
Name
V101
Magnetron
A101
Circulator
A102
Diode Limiter
Table 7-4 Spare Fuses ( for NCM-883)
Shape (mm)
6.35
31.8
6.35
31.8
Table 7-5 Special Parts ( for NKE-316 )
Type
Manufacturer
MAF1562R
New JRC
Orient
FCX68R
Microwave
NJS6930
New JRC
7-5
7.2 TROUBLE SHOOTING
In use
Spare
Parts No.
1
3
F401
1
3
F402
Location
Scanner
Scanner
Scanner
Location
Inside processing
unit
Inside processing
unit
Code
5VMAA00116
5AJIX00027
5ATBT00006
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents