Omron SYSMAC CS Series Programming Manual page 278

Hide thumbs Also See for SYSMAC CS Series:
Table of Contents

Advertisement

PC Comparison Charts
PC Comparison Charts
Item
Auxil-
Power
Power Interruption
iary
supply
Flag
Area,
Power Interruption
contd
Time
Power ON Time
Time at Power Inter-
ruption (including
power OFF)
Power ON Time
Time at Power Inter-
ruption (including
power OFF)
Power ON Time
Time at Power Inter-
ruption (including
power OFF)
Number of Momen-
tary Power Interrup-
tions
Total Power ON Time Yes
Allocation
Format
methods
Group 2 High-den-
sity I/O Unit alloca-
tion
Word reservation
method
Spe-
CIO Area
cial I/O
Unit
alloca-
tion
DM Area
CPU
CIO Area
Bus
Unit/
CPU
Bus
Unit
alloca-
DM Area
tion
CJ Series
CS Series
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes (Number of
Yes (Number of
power interrup-
power interrup-
tions)
tions)
Yes
Allocation is
Allocation is
based on number
based on number
of words required
of words required
by Units in order
by Units and
of connection.
vacant slots are
skipped.
None
Same as for
Basic I/O
Change I/O table
Change I/O table
from CX-Pro-
from CX-Pro-
grammer.
grammer.
Allocation in Spe-
Allocation in Spe-
cial I/O Unit Area
cial I/O Unit Area
according to Unit
according to Unit
No. 10 words per
No. 10 words per
Unit for total of 96
Unit for total of 96
Units.
Units.
Allocation in
Allocation in
D20000 to
D20000 to
D29599 accord-
D29599 accord-
ing to unit num-
ing to unit num-
ber, 100 words
ber, 100 words
per Unit for total
per Unit for total
of 96 Units.
of 96 Units.
Allocation in CPU
Allocation in CPU
Bus Unit Area
Bus Unit Area
according to Unit
according to Unit
No. 25 words per
No. 25 words per
Unit for total of 16
Unit for total of 16
Units.
Units.
Allocation in
Allocation in
D30000 to
D30000 to
D31599 accord-
D31599 accord-
ing to Unit No.
ing to Unit No.
100 words per
100 words per
Unit for total of 16
Unit for total of 16
Units.
Units.
C200HX/HG/HE
CVM1/CV Series
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
Yes (Number of
Yes
power interrup-
tions)
No
No
Fixed word allo-
Allocation is
cation: Each Unit
based on number
is automatically
of words required
allocated one
by Units and
word
vacant slots are
skipped.
Group-2 alloca-
None
tion area in IR
Area (position
determined by
front panel
switch)
Create I/O table
Dummy I/O Unit
with empty slot or
or change I/O
change I/O table
table from CX-
made from CX-
Programmer.
Programmer.
Allocation in Spe-
Same as for
cial I/O Unit Area
Basic I/O Units; 2
(in IR Area)
or 4 words allo-
according to Unit
cated in I/O Area
No. 10 words per
(differs for each
Unit for total of 16
Unit)
Units.
Allocation in
None
DM 1000 to
DM 1999, and
DM 2000 to
DM 2599 100
words per Unit for
total of 16 Units.
None
Allocation in CPU
Bus Unit Area
according to Unit
No. 25 words per
Unit for total of 16
Units.
None
Allocation in
D02000 to
D03599 accord-
ing to Unit No.
100 words per
Unit for total of 16
Units.
Appendix A
Appendix A
CQM1H
No
No
No
Yes
No
Yes
No
Yes
Yes (Number of
power interrup-
tions)
No
Allocation is
based on number
of words required
by Units in order
of connection.
None
Automatic alloca-
tion at startup.
Same as for
Basic I/O Units;
1, 2, or 4 words
allocated in I/O
Area (differs for
each Unit)
None
None
None
259

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs1g/h-cpu-ev1 seriesCj1g-cpu seriesSysmac cj series

Table of Contents