FWE R-AS-10 Installation Manual & Operating Instructions page 15

Mobile refrigerated air screen
Hide thumbs Also See for R-AS-10:
Table of Contents

Advertisement

FWE MOBILE REFRIGERATED AIR SCREEN
TROUBLESHOOTING GUIDE (cont'd)
PROBLEM
8. Start capacitor open or shorted or blown.
9. Run capacitor open, shorted or blown.
10. Relay defective or burned out.
11. Suction line frosted or sweating.
12. Liquid line frosted or sweating.
13. Noisy condensing unit.
14. Error Message: "Err1"
"Err2"
"Err3"
"Err4"
"Err5"
"Err6"
"Err7"
"Err8"
POSSIBLE CAUSE/REMEDY
6. Evaporator Coil Iced - Defrost
7. Restriction In Refrigeration System - Determine Locations &
Remove
8. Dirty Condenser - Clean Condenser
9. Filter Dirty - Clean or Replace
1. Relay Contacts Not Opening Properly - Clean Contacts or
Replace Relay If Necessary
2. Prolonged Operation On Start Cycle Due To:
a) Low Voltage To Unit - Determine Reason & Correct
b) Improper Relay - Replace
c) Starting Load Too High - Correct By Using Pump Down
Arrangement If Necessary
3. Excessive Short Cycling - Determine Reason For Short
Cycling (see #6 above) And Correct
4. Improper Capacitor - Determine Correct Size
1. Improper Capacitor - Determine Correct Size & Replace
2. Excessively High Line Voltage (110% of rated max) -
Determine Reason & Correct
1. Incorrect Relay - Check & Replace
2. Incorrect Mounting Angle - Remount Relay In Correct
Position
3. Line Voltage Too High or Too Low - Determine Reason &
Correct
4. Excessive Short Cycling - Determine Reason (see #6 above)
& Correct
5. Relay Being Influenced By Loose Vibrating Mounting -
Remount Rigidly
6. Incorrect Run Capacitor - Replace With Proper Capacitor
1. Overcharge of refrigerant - Correct Charge
2. Evaporator Fan Not Running - Determine Reason & Correct
1. Restriction In Dehydrator or Strainer - Replace Part
2. Liquid Shut-Off (king valve) Partially Closed - Open Valve
Fully
1. Loose Parts or Mounting - Find & Tighten
2. Tubing Rattle - Reform To Free Of Contact
3. Bent Fan Blade Causing Vibration - Replace Blade
4. Fan Motor Bearing Worn - Replace Motor
1. Sensor Failure
2. Configuration Connector Error
3. Not Defined
4. Under Temperature
5. Over Temperature
6. Key Shorted
7. Door Switch
8. EEPROM Possible Corruption
-15-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents