Autoread_Getmessage - Siemens SIMATIC RF1000 Operating Instructions Manual

Hide thumbs Also See for SIMATIC RF1000:
Table of Contents

Advertisement

Programming
6.3 Programming via the RS232 interface (using the Freeport protocol)
6.3.2.11

Autoread_GetMessage

Max. reader response time: 100 ms
Table 6- 46
Byte
0
1
2
3 ... 4
5
Table 6- 47
Byte
0
1
2
3
4
5
6
7 ... 11
12
Table 6- 48
Byte
0
1
2
3
4
5
6
54
Request telegram
Value
Description
0x0C
Without checksum
0x1C
With checksum
0x05
DevCode of the command set containing the command to be called.
0x01
CmdCode of the command to be called.
0x00
Parameter length (0 bytes)
0x4D
Optional checksum "BCC8" (when the value "0x1C" is set in byte 0)
Response telegram without errors
Value
Description
0x0C
Without checksum
0x1C
With checksum
0x05
DevCode of the command set containing the command to be called.
0x01
CmdCode of the command to be called.
0x07
Parameter length (7 bytes)
0x00
0x00
Message type
0x05
Message length (e.g. 0x05)
0x11
Data from the user memory (e.g. 0x11)
0xXX
Optional checksum (when the value "0x1C" is set in byte 0)
Response telegram with errors
Value
Description
0x8C
Without checksum
0x9C
With checksum
0x05
DevCode of the command set containing the command to be called.
0x01
CmdCode of the command to be called.
0x01
Parameter length (1 byte)
0x00
0x01
Status
Possible status codes:
0x01: NO_MESSAGE_ERR
0x10: AR_DISABLED_ERR
0xDC
Optional checksum (when the value "0x9C" is set in byte 0)
Operating Instructions, 02/2020, C79000-G8976-C432-07
SIMATIC RF1000

Advertisement

Table of Contents
loading

Table of Contents