6.3.2.5

vhl_select

Max. reader response time: 3 s
Table 6- 29
Byte
0
1
2
3
4
5
6
7
8
9
Table 6- 30
Byte
0
1
2
3
4
5
6
Table 6- 31
Byte
0
1
2
3
4
SIMATIC RF1000
Operating Instructions, 02/2020, C79000-G8976-C432-07
6.3 Programming via the RS232 interface (using the Freeport protocol)
Request telegram
Value
Description
0x0C
Without checksum
0x1C
With checksum
0x01
DevCode of the command set containing the command to be called.
0x00
CmdCode of the command to be called.
0x04
Parameter length (4 bytes)
0x00
0xFF
Mask for the card type (e.g. 0xFFFF)
You can find detailed information on the card types in the section "vhl_select
0xFF
(Page 32)".
0x01
Reselect = 0x01
0x00
AllowConfig = 0x00
0xXX
Optional checksum (when the value "0x1C" is set in byte 0)
Response telegram without errors
Value
Description
0x0C
Without checksum
0x1C
With checksum
0x01
DevCode of the command set containing the command to be called.
0x00
CmdCode of the command to be called.
0x01
Parameter length (1 byte)
0x00
0x30
Card type (e.g. 0x30)
You can find detailed information on the card types in the section "vhl_select
(Page 32)".
0x0D
Optional checksum (when the value "0x1C" is set in byte 0)
Response telegram with errors
Value
Description
0x8C
Without checksum
0x9C
With checksum
0x01
DevCode of the command set containing the command to be called.
0x00
CmdCode of the command to be called.
0x01
Parameter length (1 byte)
0x00
Programming