Programming
6.3 Programming via the RS232 interface (using the Freeport protocol)
Byte
5
6
6.3.2.6

vhl_get_snr

Max. reader response time: 100 ms
Table 6- 32
Byte
0
1
2
3 ... 4
5
Table 6- 33
Byte
0
1
2
3
4
5
6
7
8
9
48
Value
Description
0x01
Status
Possible status codes:
0x01: NOTAG_ERR
0x03: HF_ERR
0x08: CONFCARD_READ
0x0C: HW_ERR
0xD9
Optional checksum (when the value "0x9C" is set in byte 0)
Request telegram
Value
Description
0x0C
Without checksum
0x1C
With checksum
0x01
DevCode of the command set containing the command to be called.
0x01
CmdCode of the command to be called.
0x00
Parameter length (0 bytes)
0x0D
Optional checksum (when the value "0x1C" is set in byte 0)
Response telegram without errors
Value
Description
0x0C
Without checksum
0x1C
With checksum
0x01
DevCode of the command set containing the command to be called.
0x01
CmdCode of the command to be called.
0x04
Parameter length, depending on card type (e.g. 4 bytes)
0x00
0x11
Serial number of the card, depending on card type
0x22
0x33
0x44
0xXX
Optional checksum (when the value "0x1C" is set in byte 0)
Operating Instructions, 02/2020, C79000-G8976-C432-07
SIMATIC RF1000