Syscmd_Get_Boot_Status - Siemens SIMATIC RF1000 Operating Instructions Manual

Hide thumbs Also See for SIMATIC RF1000:
Table of Contents

Advertisement

6.3.2.3

syscmd_get_boot_status

Max. reader response time: 50 ms
Table 6- 25
Byte
0
1
2
3 ... 4
5
Table 6- 26
Byte
0
1
2
3
4
5 ... 8
9
SIMATIC RF1000
Operating Instructions, 02/2020, C79000-G8976-C432-07
6.3 Programming via the RS232 interface (using the Freeport protocol)
Request telegram
Value
Description
0x0C
Without checksum
0x1C
With checksum
0x00
DevCode of the command set containing the command to be called.
0x05
CmdCode of the command to be called.
0x00
Parameter length (0 bytes)
0xC4
Optional checksum (when the value "0x1C" is set in byte 0)
Response telegram without errors
Value
Description
0x0C
Without checksum
0x1C
With checksum
0x00
DevCode of the command set containing the command to be called.
0x05
CmdCode of the command to be called.
0x04
Parameter length (4 bytes)
0x00
0x00
Boot status = 0x00 (OK)
0x48
Optional checksum (when the value "0x1C" is set in byte 0)
Programming
45

Advertisement

Table of Contents
loading

Table of Contents