The "Settings - Digital Outputs" Menu Item - Siemens SIMATIC RF650R Configuration Manual

Ident rfid systems
Hide thumbs Also See for SIMATIC RF650R:
Table of Contents

Advertisement

Configuring with the WBM
7.3 The menu items of the WBM
7.3.6

The "Settings - Digital outputs" menu item

In the "Settings - Digital outputs" menu item, you can set the properties of the digital outputs
and assign functions to the individual outputs. For each output there is an identical tab
divided into 2 areas:
● Basic settings
● Events
Figure 7-12
Basic settings
In the "Basic settings" area, you can make the following settings:
Note
Reaction time of the digital outputs
Note that the reaction time of the digital outputs depends on the reader load.
Table 7- 13
Boxes
Inactivity
Reset time
Toggle interval
72
The "Settings - Digital outputs" menu item
Description of the status properties
Description
Status that the output adopts following device startup.
If the reset time is set to a value ≠ 0, the output automatically returns to the
inactivity status when the reset time has elapsed. A value of 0 means that the
status of the output is not influenced by this automatic function.
Value range
Increment
If a value ≠ 0 is set, the output "flashes" if it is activated by an application or by
a function assignment. The flashing frequency corresponds to the value of the
toggle interval in milliseconds. A value of 0 means that the status of the output
is not influenced by this automatic function.
Value range
Increment
0 ... 65535 ms
1 ms
0 ... 65535 ms
1 ms
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 03/2018, C79000-G8976-C386-06