Parameter
value_rSSI
value_channel
value_power
value_polarization
value_inventoried
value_
filterDataAvailable
10.3.3.5

getObservedTagIDs

With this command, the selected read point takes an inventory and returns all identified
transponders in the reply frame.
In contrast to the "readTagIDs" command, the smoothing algorithm of the selected read point
is also affected here. The read point must therefore take enough inventories until a
transponder adopts the "Observed" status. This can be achieved by selecting the suitable
parameter values or by triggering/starting the read point in good time before the command.
If no transponder was identified with the "Observed" status, a positive reply without
transponder data is returned.
To be reported, a transponder must have had the "Observed" status at least once at the start
of or during the command execution time. The transponder is reported even if it returned
temporarily to the "Lost" status.
The command remains active during the entire duration. In the implementation of the client
application, make sure that timeout monitoring is used. The configuration parameters of the
data source (read cycles per trigger, read timeout, ...) are not used. You will find more
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 03/2018, C79000-G8976-C386-06
Type
Values
Decimal value
0...255
0...9
Decimal value
1...50
0...9
Decimal value
0, 5.00...33.00
0...9
Fixed values
Default
Circular
Linear_vertical
Linear_horizontal
All
Decimal value
0...65535
0...9
Fixed values
True
False
Programming via XML interface
10.3 XML commands
Description
Optional
RSSI value
Optional
Channel number on which the tran-
sponder was detected.
Optional
Used radiated power of the antenna in
[dB]
Increment: 0.25 dB
Optional
Polarization of the antenna
Currently, this parameter can only be
set for the internal antenna of the
RF685R.
Optional
Indicates how often the transponder
was identified via the air interface in
this command.
Optional
Indicates whether or not a filter criteri-
on was received.
True:
All the data was read or there was
no filter set.
False:
Data could not be read.
229