12.2.1

How the LED status display works

Note that the RF650R reader does not provide an LED status display. The LED status
display displays the error messages of the RF680R/RF685R readers.
Figure 12-3
Error messages are indicated by red flashing status LEDs and the red flashing "ER" LED. A
distinction is made between hardware errors (faults) and normal errors. With hardware
errors, the LEDs flash with a fast frequency of 4 Hz. With all other errors, the LEDs flash with
a slow frequency of 2 Hz.
The detailed LED error display described here is enabled as default. If required, you can
disable this in the "Settings - General" menu item of the WBM. If the LED error display is
enabled, a separate LED pattern is assigned to every error in the LED status display. The
displayed LED patterns are based on the error code of the hexadecimal error message
converted to binary.
Example
The error "0x12" (XML error message) is displayed. Converted to binary, this results in the
value "0001 0010". This converted value is displayed in the LED status display. The value
"0" means that the corresponding LED does not light up, whereas the value "1" means that
the corresponding LED is lit red. The middle (5th LED) of the LED status display serves as a
"delimiter" and is always lit yellow.
XML error message
hexadecimal
0x12
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 03/2018, C79000-G8976-C386-06
LED status display (ST1 - ST9)
LED operating display
LED displays of the RF680R/RF685R readers
Error message
binary
0001 0010
Service and maintenance
12.2 Error messages
LED fault display