Mitsubishi MELDAS HS Series Specifications And Instruction Manual page 33

Intelligent servomotor
Table of Contents

Advertisement

4) Total capacity of connected motors
The total capacity of the motors that can be
connected to the HS-IF-6 main power terminal
block is 6kW or less. If the total motor capacity
exceeds 6kW, wire with a standalone terminal
block.
(5) D/A output measurement methods
1) Remove the upper cover from the I/F unit.
2) Connect a measuring instrument to the I/F unit check pin.
Refer to the drawing on the right
for the connection sections.
3) When observing the waveform,
turn the I/F unit's servo monitor
D/A output changeover switch to
OFF (right).
4) Select the data to be measured
with the parameters. (Refer to
section "8-1. Measuring the
adjustment data".)
Always turn the DIP
switch ON before turning
the power ON. Do not
connect a measuring
instrument having a low
input impedance when
CAUTION
turning the power ON.
The "Amplifier Not
Mounted" alarm will
occur.
(6) Alarm display LED
The alarm display LED holds the state
of each axis alarm when an alarm or
emergency stop occurs.
Use this to pinpoint the cause when an
emergency stop state occurs due to a cable or amplifier fault.
The display of each LED will change as shown below.
When 200VAC is turned ON
After NC starts
Emergency stop occurrence from NC side
Emergency stop occurrence from intelligent servomotor 1st axis
Emergency stop occurrence from intelligent servomotor 2nd axis
Emergency stop occurrence from intelligent servomotor 3rd axis
Emergency stop occurrence from intelligent servomotor 4th axis
Emergency stop occurrence from intelligent servomotor 5th axis
Emergency stop occurrence from intelligent servomotor 6th axis
Chapter 4 Option and Peripheral Devices
HS motor
Terminal block
#1 1st axis display
#2 2nd axis display
#3 3rd axis display
#4 4th axis display
#5 5th axis display
#1
#2
Not set Not set Not set Not set Not set Not set Not set
Not ON Not ON Not ON Not ON Not ON Not ON Not ON
Not ON Not ON Not ON Not ON Not ON Not ON Not ON
ON
Not ON Not ON Not ON Not ON Not ON Not ON
Not ON
ON
Not ON Not ON Not ON Not ON Not ON
Not ON Not ON
Not ON Not ON Not ON
Not ON Not ON Not ON Not ON
Not ON Not ON Not ON Not ON Not ON
4–5
HS-IF-6
Alarm display LED
#7 CN1B connection axis display
#6 6th axis display
Servo monitor D/A output
changeover switch
D/A output grounding
terminal
1st axis D/A output
terminal
2nd axis D/A output
terminal
3rd axis D/A output
terminal
4th axis D/A output
terminal
5th axis D/A output
terminal
6th axis D/A output
terminal
#3
#4
#5
#6
ON
Not ON Not ON Not ON Not ON
ON
Not ON Not ON Not ON
ON
Not ON Not ON
ON
#7
Not ON