Standard Specifications - Mitsubishi MELDAS HS Series Specifications And Instruction Manual

Intelligent servomotor
Table of Contents

Advertisement

2-1 Standard specifications

(1) HS-MF, HS-RF Series (Low-inertia, small capacity/low-inertia, medium capacity)
Type
Rated output (kW)
Short-time
characteristics
Rated torque (N· m)
Rated output (kW)
Continuous
characteristics
Rated torque (N· m)
Maximum torque (N· m)
Rated rotation speed (r/min)
Maximum rotation speed (r/min)
-4
Moment of inertia J (×10
kg· m
Detector resolution/method
Voltage/frequency
Tolerable voltage fluctuation
Power
Tolerable frequency
supply
fluctuation
Power facility capacity (kVA)
Control method
Dynamic brakes
Recommended load moment of inertia
rate
Environment conditions
Structure
(2) HS-SF Series (medium-inertia, medium-capacity)
Type
Rated output (kW)
Short-time
characteristics
Rated torque (N· m)
Rated output (kW)
Continuous
characteristics
Rated torque (N· m)
Maximum torque (N· m)
Rated rotation speed (r/min)
Maximum rotation speed (r/min)
-4
Moment of inertia J (×10
kg· m
Detector resolution/method
Voltage/frequency
Tolerable voltage
fluctuation
Power
Tolerable frequency
supply
fluctuation
Power facility capacity
(kVA)
Control method
Dynamic brakes
Recommended load moment of inertia
rate
Environment conditions
Structure
Note 1: The rated output and rated rotation speed are the guaranteed values in the 200 to 230VAC 50/60Hz range. The torque-speed
line diagram indicates the characteristics when 200VAC is input. Note that the high-speed characteristics will drop when the
power voltage drops.
Note 2: Make sure that the acceleration/deceleration torque is within 80% of the maximum output torque.
Note 3: Make sure that the continuous effective load torque is within 80% of the motor rated torque.
Note 4: With the HS-MF23, if the recommended load moment of inertia rate is exceeded, an overvoltage alarm may occur because of
the speed and deceleration torque. (Refer to Chapter 11.)
Note 5: Magnetic brakes are prepared for the 0.4KW and larger capacities. The HS-MF23 does not have brake specifications.
Chapter 2 Specifications
HS-MF23
0.2/15min
0.64
0.15
0.48
1.92
2
)
0.089
8,000/absolute value
3-phase 200VAC to 230VAC 50/60Hz (HS-MF23 is single-phase)
0.5
4-fold or less when using cutting axis, 10-fold or less when using peripheral axis
Fully closed self-cooling: Protective structure IP65 (Excluding MF23 connector. Protection
HS-SF52
0.5/30min
2.39
0.4
1.91
11.8
2000
2000
2
)
6.6
1.0
4-fold or less when using cutting axis, 10-fold or less when using peripheral axis
(Protection applies for connector section when engaged)
HS-RF43
0.4/30min
1.27
0.32
1.02
3.18
3000
3000
0.8
170 to 253VAC
±5%
0.9
Sine wave PWM control, current control method
Built-in
Follows section 3-1-1 Environment conditions
applies for all connectors when engaged to machine.)
HS-SF53
HS-SF102
0.5/30min
1.0/30min
1.59
4.78
0.4
0.75
1.27
3.58
8.82
21.6
3000
2000
3000
2000
6.6
13.6
100,000/absolute value
3-phase 200VAC to 230VAC 50/60Hz
170 to 253VAC 50/60Hz
±5%
1.0
1.7
Sine wave PWM control, current control method
Built-in
Follows section 3-1-1 Environment conditions
Fully closed self-cooling: Protective structure IP65
2–2
HS-RF73
0.75/30min
2.39
0.6
1.91
5.97
1.5
100,000/absolute value
1.3
HS-SF103
HS-SF202
1.0/30min
2.0/30min
3.18
0.75
2.39
16.7
3000
3000
13.6
1.7
9.55
1.5
7.16
41.7
2000
2000
42.5
3.5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents