Connect the module within the front-door
station
After the installation into the front panel, the
modules themselves have to be wired.
The built-in door loudspeaker module can be
connected to a module with a 4-pin connect-
ing cable (e.g. bell button module):
Remove the cover of the service opening.
Guide the cable upwards from the termi-
nals and push it slightly under the module
housing. Plug the connection cable with 4
pins on the service socket in the service
opening.
Close the service opening and the terminal
cover.
Connect the module to the TCS:BUS
Das Einbau-Türlautsprechermodul wird
direkt am TCS:BUS
(3-Drahttechnik, a b P).
Notes on connecting the module with a system
3-wire technique necessary!
Connect buttons from other systems (e.g. elevator):
The buttons must be potential-free. It may be necessary to insert a relay for decoulping
in order to guarantee that the buttons are potential-free.
Connecting other consumers:
It is not allowed to connect further consumers such as tubular lamps, light bulbs or
!
others to the ASI11000. For this, a separate transformer must be used.
The max. number of indoor stations depends on the type of indoor station (comp. Pro-
duct information of the indoor station).
Attention: When using a FAA1100, the door release time of the power supply and
control unit must be set to maximum!
TCS TürControlSysteme AG, TCS Hotline Deutschland: +49 (0) 41 94 / 9 88 11 88
Fax: +49 (0) 41 94 / 9 88 129 E-Mail: hotline@tcsag.de
Connecting the lines
®
®
angeschlossen
4
AMI11100
Bell button
module l
AMI1090x
01/2013
Subject to technical changes.
PI_AMI11100-uk
1A