Download Print this page

TCS AMI Series Product Information page 6

Built-in door loudspeaker module
Hide thumbs Also See for AMI Series:

Advertisement

Error detection and indictaion
Errors are displayed optically and acoustically: one-time
error tone and constant flashing of the operation-LED,
green. When pressing a button at a connected bell but-
ton module, the error tone sounds again. The optical
error indication stays active until the error has been
fixed.
Error causes
EEPROM is missing or plugged
incorrectly
a- and P-wire interchanged or
short-circuited
a-wire not connected
Button stucks (press longer than
15 seconds)
Adjust volume of speech and acknowledgement tones
!
Use the enclosed small screwdriver to adjust the setting!
 Open the cover of the secive
openeing.
 The volume of speech (loudspeaker)
and acknowledgement tones can be
adjusted via two separate controls.
 The volume is set ex works to an
average value.
Settings ex works
Communication time
Door call standby time
Door release time
TCS TürControlSysteme AG, TCS Hotline Deutschland: +49 (0) 41 94 / 9 88 11 88
Fax: +49 (0) 41 94 / 9 88 129  E-Mail: hotline@tcsag.de
6
Display
Error tone Solution
Operation-
LED,
green
flashes
(1:7, 1 Hz)
Settings
Configuration
56 s
56 s
3 s
11
Insert EEPROM,
switch on the main voltage again!
Interchange a- and P-wire or remove short
circuit, device returns to standby mode
Connect a-wire,
device returns to standby mode
Release button,
device returns to standby mode
7
8
7 Control acknow-
8 Control volume
01/2013
11 Operation-
LED, green
ledgement tones
loudspeaker
Subject to technical changes.