Error detection and indictaion
Errors are displayed optically and acoustically: one-time
error tone and constant flashing of the operation-LED,
green. When pressing a button at a connected bell but-
ton module, the error tone sounds again. The optical
error indication stays active until the error has been
fixed.
Error causes
EEPROM is missing or plugged
incorrectly
a- and P-wire interchanged or
short-circuited
a-wire not connected
Button stucks (press longer than
15 seconds)
Adjust volume of speech and acknowledgement tones
!
Use the enclosed small screwdriver to adjust the setting!
Open the cover of the secive
openeing.
The volume of speech (loudspeaker)
and acknowledgement tones can be
adjusted via two separate controls.
The volume is set ex works to an
average value.
Settings ex works
Communication time
Door call standby time
Door release time
TCS TürControlSysteme AG, TCS Hotline Deutschland: +49 (0) 41 94 / 9 88 11 88
Fax: +49 (0) 41 94 / 9 88 129 E-Mail: hotline@tcsag.de
6
Display
Error tone Solution
Operation-
LED,
green
flashes
(1:7, 1 Hz)
Settings
Configuration
56 s
56 s
3 s
11
Insert EEPROM,
switch on the main voltage again!
Interchange a- and P-wire or remove short
circuit, device returns to standby mode
Connect a-wire,
device returns to standby mode
Release button,
device returns to standby mode
7
8
7 Control acknow-
8 Control volume
01/2013
11 Operation-
LED, green
ledgement tones
loudspeaker
Subject to technical changes.
PI_AMI11100-uk