ELECTRICAL DATA : WIRING DIAGRAMS

DIAGRAM REFERENCE LEGEND

– A1 -2-3-4
AIR SO CK CO NTRO L
– B1
EXTERNAL AIR THERMOSTAT
– B2
SMOKE DETECTION HEAD
– B3
RC CIRCUIT
– B4 - B5
G AS MANIFOLD IONISATIO N PRO BE
– B6 - B7
G AS MANIFO LD IG NITIO N ELECTRODE
– B1 0
AIR PRESSURE SWITCH
– B1 1
W ATER FLO W RATE CO NTRO LLER
– B1 3
CL OGG ED AIR FILTER PRESSURE SWITCH / AIR FLOW RATE
– B1 4
HO T WATER CO IL ANTIFREEZE THERMOSTAT
– B1 5
HO T WATER CO IL ANTIFREEZE THERMOSTAT
– B1 6
FIRE TH ERMO STAT
– B1 7 - B18
G AS MANIFOLD MINIMUM GAS PRESSURE SWITCH
– B1 9 - B20
BLO WER FAN MO TO R -MS1 - MS2 STOPTHERM
– B2 1 - B22
G AS MANIFOLD SMO KE EXTRACTIO N AIR PRESSUR E SWITCH
– B2 3 - B24
EXTR ACTIO N FAN MO TO R -ME1 - ME2 STO PTHERM
– B2 5 - B26
ELECTRIC BATTERY -E1 - E2 SAFETY KLIXO N
– B2 7
ELECTRIC BATTERY -E3 SAFETY KLIXO N
– B2 8
CIRCULATIO N PUMP -MP1 MO TO R STO PTHERM
– B2 9 - B30
G AS MANIFOLD AIR FL OW RATE SAFETY KLIXON
– B3 2 - B33
G AS MANIFOLD FL ASHBACK SAFETY KLIXO N
– B4 1 - B42
CO MPRESSOR -MG11 - 12/-MG21 - 2 2 HIGH PRESSURE SAFETY SW ITCH
– B4 5 - B46
G AS MANIFOLD 1/ G AS MANIFOLD 2 R EG ULATION KLIXO N
– B5 1 - B52
CO MPRESSOR -MG11 - 12/-MG21 - 2 2 LO W PRESSURE SAFETY SWITCH
– B6 1 - B62
CO MPRESSOR -MG11 - 12/-MG21 - 2 2 HIGH PRESSURE CONTROL SWITCH
– B7 1 - B72
CO NDENSER -MC1 - MC2 FAN MO TOR MOTOR STO PTHERM
– B7 3 - B74
CO NDENSER -MC3 - MC4 FAN MO TOR MOTOR STO PTHERM
– B8 11 - B812
SCRO LL COMPRESSOR -MG11 - 1 2 PRO TECTION MODULE
– B8 21 - B822
SCRO LL COMPRESSOR -MG21 - 2 2 PRO TECTION MODULE
– B9 1 - B92
CO MPRESSOR -MG11 - 12/-MG21 - 2 2 PRESSU RE SWITCH 4/20mA
BCD
CO NDENSER CO IL
BEC
HO T WATER CO IL
BEG
CHILLED WATER COIL
BEV
EVAPORATO R CO IL
– BG 10
HYG IENE PRO BE
– BH1 0
REG ULATION HYGRO METRY PROBE
– BH1 1
EXTERNAL HYGRO METRY PROBE
– BT10
REG ULATION TEMPERATURE PROBE
– BT11
EXTERNAL TEMPERATURE PROBE
– BT12
BLO WER TEMPERATU RE PROBE
– BT13
CO LD WATER TEMPERATURE PROBE
– BT14
CO NDENSER 1 SPEED REG ULATION TEMPERATURE PRO BE
IOM – FLEXY II – 1007 – E
– KE1 -2 -3
HEATER -E1 - E2 - E3 CO NTACTOR
– KM1 - KM2
BLO WER FAN MO TO R -MS1 - MS2 CO NTACTO R
– KM5 - KM6
EXTRACTIO N FAN MO TO R -ME1 - ME2 CO NTACTO R
– KM9 - KM10
CO NDENSER 1 / COND ENSER 2 FAN MOTOR CO NTACTO R
– KM1 1 - KM12
CO MPRESSOR -MG 11 - MG12 CO NTACTOR
– KM2 1 - KM22
CO MPRESSOR -MG 21 - MG22 CO NTACTOR
– MC1.2
CO NDENSER -MC1 - MC2 FAN MOTOR
– MC3.4
CO NDENSER -MC3 - MC4 FAN MOTOR
– ME1 - ME2
EXTRACTIO N FAN MO TO R -ME1 - ME2
– MG11 - MG 12 CO MPRESSOR -MG 11 - MG12
– MG21 - MG 22 CO MPRESSOR -MG 21 - MG22
– MR1
ECO NOMISER DAMPER MO TO R
– MR2
BLO WER DAMPER MOTOR
– MR3
NEW AIR DAMPER MOTOR
– MR4
EXTRACTIO N DAMPER MOTOR
– MR6
BY-PASS DAMPER MOTOR
– MS1 - MS2
BLO WER FAN MO TO R -MS1 - MS2
– Q1 - Q2
BLO WER FAN MO TO R -MS1 - MS2 PROTECTION
– Q5 - Q6
EXTRACTIO N FAN MO TO R -ME1 - ME2 PROTECTION
– Q9
CO NDENSER -MC1 - MC2 FAN MOTOR PROTECTION
– Q10
CO NDENSER -MC3 - MC4 FAN MOTOR PROTECTION
– Q11 - Q12
CO MPRESSOR -MG 11 - MG12 PROTECTION
– Q21 - Q22
CO MPRESSOR -MG 21 - MG22 PROTECTION
– QF1
PRIMARY CIRCU IT PRO TECTION -T1
– QF2
PRIMARY CIRCU IT PRO TECTION -T2
– QF3
PRIMARY CIRCU IT PRO TECTION -T3
– QG
MAIN SWITCH
– QE1-2-3
HEATER -E1 - E2 - E3 PRO TECTION