Power Interposer Board; Removing The Power Interposer Board - Dell DSS 1510 Owner's Manual

Hide thumbs Also See for DSS 1510:
Table of Contents

Advertisement

Related tasks
Before working inside your system
After working inside your system
Removing the control panel module
Related reference
Safety instructions

Power interposer board

The power interposer board (PIB) is a board that connects the redundant power supply units (PSUs) to the system board. The PIB is only
supported in systems with redundant PSUs.

Removing the power interposer board

Prerequisites
CAUTION:
Many repairs may only be done by a certified service technician. You should only perform troubleshooting and
simple repairs as authorized in your product documentation, or as directed by the online or telephone service and
support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow
the safety instructions that are shipped with your product.
NOTE:
The power interposer board (PIB) is present only in systems that support redundant power supply units (PSUs).
1. Follow the safety guidelines listed in the Safety instructions section.
2. Follow the procedure listed in the Before working inside your system section.
3. Remove the PSUs from the system.
Steps
1. Disconnect the power distribution cables from the system board.
2. Disconnect the fan cable.
3. Remove the two screws securing the PIB to the chassis and lift the board out of the chassis.
Figure 71. Removing the PIB
1. standoffs (2)
114
Installing and removing system components
2. PIB