Nortel Ethernet Power Supply 10 Power Specification; Nortel Ethernet Redundant Power Supply 15 Power Specification; Nortel Ethernet Dc-Dc Converter Module - Nortel 5500 series Installation Manual

Hide thumbs Also See for 5500 series:
Table of Contents

Advertisement

32 Installing the Nortel Ethernet Routing Switch
Maximum Thermal Rating:
Inrush Current:
Turn on Condition:
Efficiency:
Nortel Ethernet Power Supply 10 power specification
Output Current:
Output Voltage:
Output Power:
Nortel Ethernet Redundant Power Supply 15 power specification
A DC power supply used with the AC power supply to provide DTE power to
all of the PoE ports in the Nortel Ethernet Routing Switch 5520.
RPS power specifications
Input Voltage:
Input Current:
Inrush Current:
Output Voltage:
Output Current:
Output Power:

Nortel Ethernet DC-DC converter module

The Nortel Ethernet Routing Switch 5510 requires an additional DC-DC
converter module to make use of the Nortel Ethernet Routing Switch
Redundant Power Supply Model 15 (RPS 15). This module is required
to connect the RPS 15 to the Nortel Ethernet Routing Switch 5510 but
is not required for other switches in the 5500 Series. For information on
connecting this module to the 5510, see DC-DC Converter Module for the
Baystack 5000 Series Switch (Part Number 215081-A).
Copyright © 2005 - 2006, Nortel Networks
.
Nortel Ethernet Routing Switch 5500 Series
Installation
NN47200-300 2.00 Standard
5.0 7 July 2006
512 BTU/Hr
20A 120VAC at maximum load, 40A
240VAC at maximum load
1 second maximum after application of AC
power.
Note: 12V output rise time, from 10% to
90%, shall be a maximum of 50 ms and
monotonic under all defined input and
output conditions.
70% minimum
4.2A maximum
-48 VDC
200W maximum
100 to 240 VAC 50/60 Hz
10A maximum
40A maximum (regardless of ambient
temperature)
47.5 VDC
12.0A
600W