Chapter 4
4.3.15 Linear Encoder Sensor
iPF810 / iPF820
a) Removing the linear encoder sensor
1) Remove the carriage unit.
2) Remove screw [1] and connector [2] and remove linear encoder sensor [4] by moving it slantwise upward to release from two bosses [3].
b) Removing the linear scale
1) Open the ink tank unit wide until it stops.
2) Remove the spring [1] and the hook [2] to remove the linear scale [3].
c) Precaution in mounting the linear encoder sensor/linear scale
Check that linear scale [1] is seated within linear encoder sensor [2].
4-48
[3]
F-4-113
[2]
[3]
F-4-114
[2]
F-4-115
[2]
[1]
[1]
[1]
[4]
0020-5676