The photointerrupter-based media take-up on/off sensor detects the switch status of the media take-up unit.
When the media take-up switch is set to ON, the sensor arm transmits the sensor light, power-on the media take-up unit.
When the media take-up switch is set to OFF, the sensor arm shields the sensor light, shutting down the media take-up unit.
Media take-up paper detection sensor
When the sensor light is shielded by a loop of printed paper, the media take-up motor rotates to take up the paper.
2.5.6 Others
iPF810 / iPF820
Temperature/humidity detection sensor
The temperature/humidity detection sensor detects the temperature and relative humidity around the printer to implement head height adjustment, maintenance jet
control, waste ink evaporation calculation and suction fan control on the basis of the temperature and relative humidity thus measured.