When filling the bath or if the water has been turned off
Be careful not to overfill the bath. An average bath volume is 160 L. It is
recommended that when filling a bath for the first time you should:
remain by the bath during the filling process
use a low bath fill volume such as 60 L or less
If the shower saver / bath fill is interrupted (water is turned off) for any reason and there is more
than half the volume of the set amount of water delivered, the shower saver / bath fill will reset
itself back to normal when the operation is turned on again, refer examples below.
Set
Delivered volume
volume
(bath fill interrupted, tap closed)
160 L
50 L
160 L
110 L
Using shower saver / bath fill
Press the shower saver / bath fill button once. The button will illuminate and a voice
prompt and tone will sound. During shower saver / bath fill, the bath indicator will also be
displayed on the Kitchen Deluxe controller.
The voice prompt will say 'The hot water system is ready. Open the hot water tap'. Open the hot
water tap for the shower or bath.
To stop the shower saver / bath fill
To stop the water flow while in shower saver / bath fill, press the Shower Saver / Bath Fill button.
The button will flash and a voice prompt will say 'Hot water is not available. Turn off all hot water
taps and push the bath fill button'—follow the voice prompt instructions.
When shower saver / bath fill operation finishes
Once shower saver / bath fill is finished the following occurs:
1. Flow from the shower / bath stops
2. Shower Saver / Bath Fill button flashes
3. Kitchen Deluxe controller if fitted will flash with a bath indicator
4. A tone will sound
5. A voice prompt will say 'Bath fill is complete. Turn off the bath hot water tap and push the Bath
Fill button'
Follow the voice prompt instructions. Please note that the water heater will not allow hot water to
flow from any fixture until the Shower Saver / Bath Fill button has been pressed.
Using multiple controllers
The Rinnai INFINITY can be turned on and off at any water controller. If more than one controller is
fitted, press the Transfer button to transfer priority to the desired water controller.
12 | Rinnai INFINITY Deluxe controller OIM 01-20
Delivered volume
(bath fill restarted, tap turned on again)
110 L
Resets back to normal operation, bath fill
will only be 110 L