Checking the gas settings

Supply pressure check
1. Close the gas valve.
2. Loosen screw "b" and insert the pressure gauge
connection pipe into the pipe tap.
3. Open the gas valve.
4. Switch the appliance ON by opening a DHW tap.
The supply pressure should correspond to the value
established in relation to the type of gas for which the
appliance is designed.
WARNING!!
Should
the
power
correspond to what indicated on the Gas
Summary Table, DO NOT ACTIVATE THE
DEVICE.
5. Switch the appliance OFF by closing the DHW tap.
6. Close the gas valve.
7. When the check is over, tighten screw "b" and make
sure it is securely in place.
8. Open the gas valve and check the tightness of the
screw.
commissioning
pressure
not
Verifica della regolazione gas
Controllo della pressione di alimentazione
1.
Chiudere il rubinetto gas
2.
Allentare la vite "b" ed inserire il tubo di raccordo del
manometro nella presa di pressione.
3.
Aprire il rubinetto del gas
4.
Mettere l'apparecchio in funzione aprendo un
rubinetto dell'acqua calda sanitaria.
La pressione di alimentazione deve corrispondere a
quella prevista per il tipo di gas per cui l'apparecchio
è predisposto.
ATTENZIONE!!
SE LA PRESSIONE DI
ALIMENTAZIONE NON
CORRISPONTE A QUANTO INDICATO
NELLA TABELLA RIEPILOGATIVA
GAS NON METTERE IN FUNZIONE
L'APPARECCHIO.
5.
Spegnere l'apparecchio chiudendo il rubinetto
dell'acqua calda sanitaria
6.
Chiudere il rubinetto del gas
7.
Staccare il manometro e stringere la vite "b".
8.
Aprire il rubinetto del gas e verificare la tenuta della
vite di misurazione.