Electrical Connection; Configuration - Potterton SIRIUS THREE FS 130 Installation, User And Service Manual

Floor-standing condensing gas boiler
Table of Contents

Advertisement

Fig.56
Boiler + 1 underfloor heating circuit + 1 direct circuit + 1 domestic hot water tank
34
26
11
2 Heating pump
11 Heating pump
21 Outside temperature sensor
26 DHW booster pump
33 Domestic hot water temperature sensor
34 Primary pump
38 Room temperature sensor
Tab.15
Boiler settings + 1 underfloor heating circuit + 1 direct circuit + 1 domestic hot water tank
Parameter number
5715
6020
6024
7702639 - v03 - 10072018
6.2.2
158
AVS75
4
3
117
2
2
1
6.2.3
1. Go to the installer parameters.
2. Set the following parameters on the boiler:
Parameter
Temps / mode CH2
Function extension module 1
Funct input EX21 module 1

Electrical connection

167
X40
X41
44
44 65 °C safety thermostat with manual reset for
underfloor heating (France: DTU 65.8, NF
P52-303-1)
117 Three-way mixing valve
158 Flow temperature sensor
167 Boiler control panel
Important
Relay the pumps if the current exceeds 1 A max per output.

Configuration

Adjustment required
On
Temps / mode CH2
Limit thermostat CH
6 Connecting diagrams and configuration
21
1 2 3
MW-3000115-07
33
38
38
1 2 3
49