3 Technical specifications
3.2

Technical data

Tab.2
General
Useful heat output at 80/60°C
Heating mode
Useful heat output at 80/60°C
Heating mode
Useful heat output at 50/30 °C
Heating mode
Useful heat output at 50/30 °C
Heating mode
Heat output
Heating mode
Heat output
Heating mode
Heat output
Heating mode
Heat output
Heating mode
Efficiency at 80/60 °C
Heating mode under full load
Efficiency at 50/30 °C
Efficiency
Return temperature 30 °C
14
CE number
NOx class
Gas and pressures
Tab.1
Type of flue gas connection
Boiler model
SIRIUS THREE FS 130
SIRIUS THREE FS 150
SIRIUS THREE FS 200
SIRIUS THREE FS 250
Boiler speed
Unit
Minimum
kW
Maximum
kW
Minimum
kW
Maximum
kW
Minimum
kW (LHV)
Maximum
kW (LHV)
Minimum
kW (HHV)
Maximum
kW (HHV)
Maximum
%
Heating mode un­
%
der full load
Heating mode un­
%
der part load
0085CP0089
Class 6
Natural gas (G20) - 20 mbar
Propane (G31) - 37/50 mbar
Type of flue gas connection
B
– B
23
C
13(X)
C
33(X)
C
43(X)
C
53(X)
C
63(X)
C
83(X)
B
– B
23
C
13
C
33
C
43
C
53
C
63
C
83
SIRIUS
SIRIUS
THREE FS
THREE FS
130
150
24.3
28.1
121.5
140.3
26.2
30.2
130.6
150.9
24.8
28.6
123.8
143
27.5
31.7
137.4
158.7
98.1
98.1
105.5
105.5
108.5
108.5
23(P)
23(P)
SIRIUS
SIRIUS
THREE FS
THREE FS
200
250
31.0
38.8
185.9
232.8
33.1
41.7
200
250
31.8
40
191
240
35.3
44.4
212
266.6
97.32
97.02
104.2
104.2
109.1
109.1