10 Settings
Parameter
Parameter
number
5931
Sensor input BX2
5932
Sensor input BX3
5970
Function input H4
5971
Contact type H4
5973
Frequency value 1
H4
5974
Function value 1 H4
5975
Frequency value 2
H4
5976
Function value 2 H4
92
Description
None : No function on the sensor input.
Hot water sensor B31 : Sensor in the bottom section of the domestic
hot water tank.
Collector sensor B6 : Solar collector sensor.
HW circulation sensor B39 : Circulation / DHW preparation sensor.
Buffer sensor B4 : Sensor in the top section of the storage tank.
Buffer sensor B41 : Sensor in the bottom section of the storage tank.
Flue gas temp sensor B8 : Flue gas sensor
Common flow sensor B10 : Common flow sensor (cascade).
Solid fuel boiler sensor B22 : Sensor for solid fuel boiler.
HW charging sensor B36
Buffer sensor B42 : Third sensor (in the middle) of the storage tank.
Common return sensor B73
Cascade return sensor B70 : Cascade return sensor.
Swimming pool sensor B13 : Swimming pool sensor.
Solar flow sensor B63 : Solar flow sensor for measuring efficiency.
Solar return sensor B64 : Solar return sensor for measuring efficien­
cy.
Primary exch sensor B26
See
Sensor input BX2
None : Default setting for boilers with domestic hot water tank.
Flow measurement Hz : Default setting for instantaneous boilers.
Error/alarm message
NC
NO
Definition of the parameters for collector specifications
Definition of the parameters for collector specifications
Definition of the parameters for collector specifications
Definition of the parameters for collector specifications
Factory set­
ting
None
None
None
Error/alarm
message
15
20
162
120
7702639 - v03 - 10072018