smoke chamber insulation panel installation

note:
For clarity purposes, some parts of the appliance have been hidden.
1. Slide front baffl e (1) up and out of retaining
bracket and pivot straight down and out of
smoke chamber. Repeat for rear baffl e (2).
3. Remove 2 screws from front right bracket and
slide front right panel (1) out of smoke chamber.
Repeat for front left panel (2).
2
5. Remove 2 screws from bracket and slide upper right
side panel (1) out. Repeat for upper left side panel
(2).
note:
Smoke chamber insulation panels are fragile. Handle with care.
32
W415-1720 / 08.21.17
2
1
1
2
2. Remove 2 screws from both brackets then slide
lower right side panel (1) out. Repeat for lower
left side panel (2).
2
4. Remove 2 screws from rear panel bracket and
remove rear panel.
6. Slide upper left side panel into smoke chamber
and install the bracket removed in step 5.
Repeat for upper right side panel.
7. Slide lower right side panel into smoke chamber
and install brackets removed in step 4. Repeat
for lower left side panel.
8. Slide rear panel into smoke chamber and install
bracket removed in step 3.
9. Slide front panel into smoke chamber and install
brackets removed in step 2.
10. Slide rear baffl e into smoke chamber and install
bracket removed in step 1. Repeat for front
baffl e.
fi nishing
1