Technical specifications and drawings
B.2 Environmental conditions
The EC declaration of conformity for the product described here, which complies with the
European Directive 2006/95/EC and corresponding standards EN 61800-5-1 and EN 60204-1,
refers only to the low-voltage section in the power unit and the control cabinet.
B.2
Environmental conditions
Climatic environmental conditions
Table B-2
Climatic environmental conditions
Ambient temperature
Relative humidity
Other climatic conditions ac‐
cording to class
Pollution degree
Mechanical ambient conditions
Table B-3
Mechanical ambient conditions
Class
110
Storage with suitable packag‐
ing
-25° C to +70° C
5% to 95%
(Only low condensation is
permitted. The device must
be completely dry before
commissioning.)
1K3 according to DIN EN
60721‑3‑1 (IEC 60721‑3‑1)
2 without conducting contam‐
ination according to DIN EN
61800-5-1 / VDE 0160 T105
(IEC 61800-5-1)
Storage with suitable packag‐
ing
1M2 according to
DIN EN 60721‑3‑1
(IEC 60721‑3‑1)
Transport with suitable pack‐
aging
-25° C to +70° C
5% to 75%
2K2 according to DIN EN
60721‑3‑2 (IEC 60721‑3‑2)
2 without conducting contam‐
ination according to DIN EN
61800-5-1 / VDE 0160 T105
(IEC 61800-5-1)
Transport with suitable pack‐
aging
2M2 according to
DIN EN 60721‑3‑2
(IEC 60721‑3‑2)
Operating Instructions Rev.201910281433 EXAMPLE
Operation (industrial)
5° C to +40° C
5% to 85%
(Condensation is not permit‐
ted)
3K3 according to DIN EN
60721‑3‑3 (IEC 60721‑3‑3)
2 without conducting contam‐
ination according to DIN EN
61800-5-1 / VDE 0160 T105
(IEC 61800-5-1)
Operation
3M1 according to
DIN EN 60721‑3‑3
(IEC 60721‑3‑3)
SINAMICS SL150 6SL38600UL432AA0Z